Welcome to TAB Technical Services
About Us
TAB TECHNICAL SERVICES is an independent testing agency, Located in Chennai & Kottayam (Kerala)
Team of experienced engineers .We provide a high quality, responsive, reliable and cost effective range of TAB services and would like the opportunity to demonstrate how this can help your business premises .The company is one of the most outstanding and fast- growing in the field of duct Testing & Commissioning Management Services. TAB Technical services was established to provide technical services for commercial, residential, and industrial sectors, our team comprised of fully qualified, experienced engineers and technicians dedicated to providing a truly independent service. Our history covers almost every MEP application including Airports, pharmaceutical production facilities, hospitals, libraries, hotels, malls,residential and commercial complexes, etc.
TAB TECHNICAL SERVICES is always capable of meeting the demands to mobilize required number of trained and qualified resources equipped with adequate instruments and tools to comply with any project execution schedule. We committed to provide quality services to our clients, in a timely manner and within budget.
Our Employees
We have high skilled engineers with excellent technical knowledge and experience In Testing and commissioning of HVAC Systems. Senior staff gained extensive experience in executing many different types of projects with many different systems.
Services
HVAC Functional Performance including Startup
Functional performance test allows us to better understand the “brains” behind why equipment performs and reacts as it does .To make sure a piece of equipment works as intended and can provide the expected performance is the main reason to functionally test HVAC systems.
TAB Technical Services offers there assurance the systems are working correctly and as intended
Testing
.
Balancing
.
Adjusting
.
Testing Commissioning (HVAC system)
Our TAB specialist ensures to achieve optimum performance of the building HVAC equipment by adjusting and balancing the air and water system. TAB Specialist performs air and hydronic measurements on the MEP systems and adjusts the flow rates as required for achieving optimum performance of the building environmental equipment
Air Balancing
HVAC air balancing is a commissioning procedure that involves the adjustment of dampers in the ductwork and the fine-tuning of the airflow at each diffuser and grille to ensure that all diffusers and grilles have equal and balanced airflow.
Purpose of Air Balancing in HVAC
Air balancing is essential for the health of the HVAC system. Without air balancing work, the newly installed HVAC system will not perform as intended. Air balancing is applicable to HVAC systems that use ductwork. For instance, ducted air conditioning, toilet exhaust system and smoke extraction system.
Instruments used for Air balancing
Water Balancing
Hydronic balancing is important to the efficiency and effectiveness of chilled water system.
Why Hydronic Balancing is Needed?
In order for the AHUs and FCUs,CSU’s to cool properly, manufacturers specified the required amount of chilled water flow rate based on the cooling capacity.
In other words, each unit has its required chilled water flow rate. The chilled water is distributed by the chilled water pumps. However, AHUs and FCUs near the chilled water pumps tend to have a higher water flow rate than the AHUs and FCUs located far away from the chilled water pumps. Consequently, AHUs and FCUs,CSU installed far away from the chilled water pumps may not receive sufficient chilled water flow rate and thus, they may not able to provide sufficient cooling.
So, hydronic balancing is extremely important in chilled water system to ensure that every AHU and FCU,CSU is receiving sufficient chilled water flow rate as per the design and requirement.
Instruments used for Water balancing
Noise level measurement
Unwanted noise is nuisance .The most common problem in a room is too much echo or reverberation .Too much echo can garble speech clarity and intelligibility.
It is to ensure the noise level of all HVAC system within the limit recommended by the NEBB standard.
Temperature measurement
Temperature can be a particularly important measure in the built environment when considering thermal comfort of occupants and in the design of building services systems.
Air conditioner temperatures that are too high or too low indicate specific cooperating problems on central and portable or window air conditioners. Our team measures the air temperatures and assists in diagnosing what may be wrong and what repairs may be needed for the air conditioner.
Relative Humidity Measurement
Office humidity is very important for every building. If it’s too high or too low, it can affect your health, the building materials, the equipment, and more. Uncontrolled humidity levels are one of the main factors for poor indoor air quality (IAQ).
When your office humidity level is too high ,it allows dust mites and microbes to grow. The air becomes moist, and mold can start to appear. On the other hand ,low humidity can also be Troublesome. Dry air makes it difficult for some people to breathe, and it can irritate the skin, eyes.
Relative humidity chart
We measure there lative humidity level to optimize the conditions inside
a building and to ensure comfort and safety to its users or residents, by
keeping indoor air quality high.
Vibration Measurement
Vibration in its simplest form can be considered an oscillation or repetitive motion of an object around an equilibrium position. In the HVAC industry, sound is not generated without some form of vibration from equipment. Although sound is not present without vibration, there can be vibration without sound noticeable to the human ear.
CHILLED WATER SYSTEM FLUSHING
The main objective of chilled water flushing process is to remove, as much dirt and debris from the pipes work system as possible, in order to reduce the livelihood of the system blockage. The process involves various stages
- Initial static flushing with plain water and strainer cleaning.
- Dynamic flushing
- Chemical flushing
Completed Projects
Project Name: Kochi Airport Business Jet Terminal
Project Name: METROBHAVAN, CMRL METRO, CHENNAI
Project Name: Kochi Business Jet Terminal
Project Name: Quest, Techno park Trivandrum, Kerala
Project Name: Lulu International Convention Centre, Trissur
Project Name: Mc Donald In Marina Mall
Project Name: ISRO Sreehari Kotta
Project Name: Dr.Km Cherian Institute Of Medical Sciences
Project Name: Lu Lu Cyber Tower, Kakkanad , Kochi
Project Name: Lakeshore hospital,kochi , Kerala
Project Name: Ksdp ,Kalavoor, Alappuzha
Project Name: Lulu Group India Head Office, Edappally, Kerala
Project Name: Vijaya international convention centre, tiruvalla,kerala
Project Name: PPC , Kerala
Project Name: Lu Lu celebrate , Edappally, Kerala
Contact Us
Head Office
Nandampakkam
Kundrathur, Chennai 600069.
Kerala Office
Kottayam, kerala
Pincode 686146
+91 6380513174 , +919895807254
Email Us
tabtechnicalservice@gmail.com , tabtechnicalservicekerala@gmail.com